Staco offers a broad range of power quality products and the expert knowledge to know which technology is right for you.
- Emergency Lighting Inverter (ELI)
- Variable Transformers & Test Sets
- Power Factor Correction & Harmonics Mitigation
- Regulation & Power Conditioner
- Frequency Conversion
- Battery Monitoring
Staco Energy ensures continuous uptime of your critical operations. Whether you’re in a data center, medical facility, government agency, or manufacturing plant, we collaborate with you every step of the way.
STACO 924 - Single Phase ELI
Single Phase, On-Line Double Conversion Emergency Lighting Inverter Systems (ELIS)
The Staco 924 full range of centralized lighting inverters extend from 0.95kW to 27kW and provide full power protection for all emergency lighting applications.
The Voltage and Frequency Independent (VFI) design provides exceptional voltage regulation and ensures lumens, drivers and ballasts on the Staco 924-protected circuit are fully operable when most needed – for egress lighting.
With the highest level of power protection, a full range of power capacities to fit installation needs, and one of the best warranties in the industry, the Staco 924 is the ideal solution for all emergency lighting requirements.
FirstLight P924
Three Phase, On-Line Double Conversion, UL924 Central Lighting Inverter
58.5-225 kW
Emergency Lighting System
FirstLine® P 924 is the result of your demand for an Emergency Lighting solution tailored to meet your requirements for a reliable, cost effective alternative for Emergency Lighting applications that help ensure the safety of your most important asset — your people. FirstLine® P 924 provides that solution with its easy-to-manage double conversion power electronics and battery system and its rugged all steel construction.
What is an Emergency Lighting Inverter?
The National Fire Protection Association (NFPA) has written Life Safety Code® (NFPA 101®*) that defines the requirements for emergency lighting for means of egress. The standard requires that emergency illumination shall be provided for not less than 1-1/2 hours (90 minutes) in the event of failure of normal lighting. Installation and testing requirements are written in the National Electric Code® (NFPA 70®*). The FirstLine® P 924 is a central system battery back-up to meet these requirements. In the event of an AC power failure, FirstLine® PL 924 automatically supports the connected lighting loads on battery power and will continue to provide power without any interruption for a full 90 minutes. When the utility power returns to normal, FirstLine® P 924 will automatically recharge the batteries to be ready for the next power disturbance. In addition to meeting life safety requirements, the FirstLine®P 924 can also increase the life expectancy of the protected lighting system and reduce long-term cost of ownership.
StacoVAR
Power Factor Correction
240-480 VAC up to 2400 kVAR
Three phase Automatic Power Factor Correction with Filter option, with or without detuning reactors, at low voltage.
Reactive Power & Harmonic Compensation
Reactive Power Compensation, or power factor correction, can lower your utility bills starting on the day the equipment is installed. Installation is fast and easy, minimizing downtime. After the equipment is installed, you should notice an immediate improvement in power factor, more efficient use of your power system’s load, and of course, monthly savings in your electric utility bills.
Staco Energy Products Company’s harmonic filters perform mitigation for a wide array of needs. This includes equipment to help reduce amplification of harmonics when capacitors are automatically switched, to suppress one or more specific harmonic orders, and to lessen a broad range of multiple harmonic orders.
StacoSINE Plus
Active Harmonic Filter
480VAC 100-1200A
Three phase Active Harmonic Filtering to meet IEEE 519 Standard. Active harmonic filter up to the 51st harmonic from 100-150amps with variable power factor and harmonic control output. Capable of paralleling up to 1200 amps.
The StacoSine® Plus active harmonic filter is available in 100 and 150 amp assemblies. Modules can be paralleled for a maximum capacity of 1200 amps of harmonic mitigation. When multiple units are paralleled only one controller in one of the modules is needed to assure proper harmonic mitigation. This controller has a touch screen that allows for easy onsite programming. Besides correcting up to the 51st harmonic, the unit can compensate for both lagging and leading reactive power, and can be programmed from 0.7 lagging to 0.7 leading power factor.
FirstLine P/FC
Three Phase
Frequency Converter 480 VAC, 52-400 kVA
Three phase Frequency Converter, 60Hz/50Hz for export product testing or operation of equipment rated at international frequency and voltage.
This product converts standard 480 VAC 60 Hz power to a selectable and precise 380, 400 or 415 VAC +/- 2% 50 Hz power. In the event of a power failure, the unit can be equipped with an optional battery cabinet to ride through a limited outage.
FirstLight PLT/FC
Three Phase
Frequency Converter 208 VAC, 10-60 kVA
Three phase Frequency Converter, 60Hz/50Hz for export product testing or operation of equipment rated at international frequency and voltage.
This product converts standard 208 VAC 60 Hz power to a selectable and precise 208 VAC +/- 2% 50 Hz power. In the event of a power failure, the unit can be equipped with an internal or an optional battery cabinet to ride through a limited outage.